Size and pressure
PN3
DN20
Flow sensing:
Magnetic pull back paddle
Mounting:
1” barbed for soft tube
Contact:
Reed switch, close on flow rise
Electrical rating
Mounting position
Type
R1Q
1: Paddle 2: Snap-on mounting 3: Connection cable 4: Adjustment screw 5: Air bleed outlet
Calibration | *Close | **Open |
Low span end (1gr) | 4,3 | 3,7 |
Middle span (2grs) | 5,7 | 4,8 |
High span end (4grs) | 7,4 | 6,9 |
* Close by flow rise (L/min) of contact open at no flow
position ** Open by flow decrease (L/min) of contact open at
no flow position. Average values for indication only. Standard tolerances ±30% Liquids temperature range: 5 to 45°C Ambient temperature range: 5 to 45°C Ingress protection: IP65 Electrical connection: 2 x AWG24 (0.2mm²) cable, PVC insulation, T80°, style UL2464. Installation instructions: Water circuit in spas and pools can contain air bubbles, it is important to prevent them stagnate in the unit of measure and originate false flow measurement. Therefore the air bleeding orifice must be located above and connected Options: cable with connector or terminals, other cable length. |
References | ||||
Cable length | ||||
500mm | 1m | 2m | 3m | |
Calibration | ||||
Low span end (1gr) | R1Q613348S15P050 | R1Q613348S15P100 | R1Q623348S15P200 | R1Q613348S15P300 |
Middle span (2 grs) | R1Q623348S15P050 | R1Q623348S15P100 | R1Q623348S15P200 | R1Q623348S15P300 |
High span end (4grs) | R1Q643348S15P050 | R1Q643348S15P100 | R1Q643348S15P200 | R1Q643348S15P300 |