In these boxes, the thermostat, bimetal disc type, is over-molded, and is thermally insulated from
the wall on which it is mounted.
Its temperature sensing cup is mechanically protected by a grid. It is located in front of the
enclosure to be in an area of natural circulation of air.
Mounting: Wall, by external side brackets. These tabs can be folded inwards. There also is the opportunity to practice two mounting holes inside for wall mounting (Note: in this case the ingress protection class IP65 on the rear wall is lost)
Protection: IP65 (IK 03 On thermostat guard, IK10 the rest of the housing)
Material: ABS-PC black glass-fiber reinforced
Screws: Stainless steel, captive
Output: 2 Cable glands M20, PA66, IP66, for cable 6 to 12 mm dia.
Electrical rating: Single pole, 8 to 16A 250V (100000 cycles). Contact style can be open on rise or close on rise.
Pilot lights: allow to visualize the power supply and thermostat contact position
Identification: The cover can be fitted with a 20x40mm riveted stainless steel identification plate (standard) or with a sticker (Option)
Customization: On request (MOQ apply)
Connection: Built in 4mm ² screw terminal block
Options:
- Other calibration temperatures
- Cream color housing
- Incorporation of a temperature sensor (thermocouple, Pt100 or Pt1000, thermistor)
- 115V pilot lights
Calibration temperature °C (°F) | Close temperature °C (°F) | Electrical rating | Main uses | References |
8°C (46,4) | 3°C (37,4) | 8A250V | Ice detaction, starts an antifreeze or heating system | Y20D9Z00805HCSV0 |
10°C (50) | 4°C (39,2) | 10A250V | Ice detaction, starts an antifreeze or heating system | Y20D9P01006CUSV0 |
10°C (50) | 4°C (39,2) | 16A250V | Ice detaction, starts an antifreeze or heating system | Y20D9J01006CUSV0 |
30°C (86) | 20°C (68) | 10A250V | Over-heating detection in residential premises, heating stop | Y20D9P03010CUSV0 |
20°C (68) | 30°C (86) | 10A250V | Over-heating detection in residential premises, alarm (NO contact) | Y20D9Q03010CUSV0 |
70°C (158) | 60°C (140) | 10A250V | Fire detaction (withstand sprinklers water sprays) | Y20D9P07010CUSV0 |