SPNO contact : Type ZA
Uses: Low voltage, high sensivity
Main applications: Electronic circuits. Pressure sensing on water heaters. This
pressure switch is more sensible than snap action models and can be calibrated at lower
pressure values. Very small differential.
Membranes: EPDM, dia 22 mm. Silicone or NBR on request
Fluid: water or air
Fitting: Plastic
Pressure: positive
Housing: PA66, UL94 VO
Contact: single pole normally open, slow make.
Electrical rating:
- Silver contact: max 1A 250V
- Gold plated contact: max 100 mA, 24V
Action: momentary, close on pressure rise.
Set point calibration: factory calibrated and sealed, not field
adjustable
Set point calibration limits: standard calibration 150mbar, other values are
achievable from 100 to 1300 mbar
Electrical connection: 6.35 x 0.8 mm quick connect terminals
Maximum pressure: 2 bars (29 PSI)
Ambient temperature limits: 0 to 85°C
Available pressure inlet fittings 1
References ( with calibration at 150 mbar): | |||||
Pressure inlet | Silver contact | Gold plated contact | |||
1/8’’ NPT | ZA2X28EA0A500000 | ZA2X28EG0A500000 | |||
1/4’’BSPP | ZA2X2QEA0A500000 | ZA2X2QEG0A500000 | |||
M10 x 1 | ZA2X2MEA0A500000 | ZA2X2MEG0A500000 | |||
Snap in fitting, 2 grooves dia 7.8 | ZA2X2TEA0A500000 | ZA2X2TEG0A500000 | |||
Snap in fitting, 1 groove dia 10 | ZA2X2ZEA0A500000 | ZA2X2ZEG0A500000 | |||
Snap in fitting, 1 spout dia 6 mm | ZA2X2AEA0A500000 | ZA2X2AEG0A500000 |
Other set point values: replace A50 in the product reference by the requested value in mbar