Blue Ink is member of Ultimheat Alliance Controls and heating equipments

Blue Ink is member of Ultimheat Alliance Controls and heating equipments

Select language

ULTIMHEAT : IP65 aluminum enclosure, for pipes, surface temperature control. Y108

Pipe temperature control thermostats (Liquid expansion measurement)

Type
Control

Adjustment
Internal

Contact
Single pole

Measurement
Pipe mounting

Range °C

Model

Y10

Thermostat

8G

Main features

Applications:

Pipe surface temperature control in usual industrial application and environment, (Not suitable for hazardous areas)
Internal adjustment is convenient for products that must not be frequently adjusted.
Standard electrical and mechanical life model

Housing: Aluminum,IP65, IK10, 104 x 102 x 86 mm, with backside pipe mounting temperature sensing aluminum bracket Grey RAL7032 epoxy painting

Set point adjustment ranges: -4-40°C (40-105°F), 30-90°C (85-195°F), 30-110°C (85-230°F).

Temperature adjustment: Set point adjustable by temperature printed internal knob. Shipped with °C printed skirt fitted on the knob, and °F printed skirt in spare part. Printed skirt is replaceable without tool.

Action: Temperature control.

Sensing element: Liquid expansion bulb inside aluminum bracket in contact with the pipe surface.

The bracket design provides optimized thermal contact with 34 mm (1”, DN25), 60 mm (2”, DN50) and 90 mm (3”, DN80)outside diameter tubes. For intermediate sizes, we recommend the use of thermal grease

Electrical connections: Internal, on screw terminal connection block

Earthing: On internal screw terminal

Cable output: M16 cable gland, PA66, for cables up to 10 mm dia.

Mounting: The thermostat housing can be fixed on the pipe by worm drive hose clamps (DIN3017) , nylon cable ties (Tie wraps upon EN50146, for applications at permanent temperature lower than 85°C), or specific stainless steel punched band (see accessories at the end of this catalog)

Identification: 20 x 40 mm stainless steel identification label, riveted.

Contact: SPDT

Electrical rating:
- Open on temperature rise contact (C-1) 16A(2.6) 250VAC
- Close on temperature rise contact (C-2) 6A(0.6) 250VAC
- Electrical life >100.000 cycles.
Cannot be used in 400VAC

Minimum Storage temperature: -35°C (-30°F)

Main references
Temperature adjustment ranges °C (°F) References Differential °C (°F) Max. temperature on tube °C (°F)
4-40°C (40-105°F) Y108GB004040AA6T 3±2°C (5.5±3.6 °F) 60°C (140°F)
30-90°C (85-195°F) Y108GB030090AA6T 4±3°C (7±5.5 °F) 120°C (250°F)
30-110°C (85-230°F) Y108GB030110AA6T 5±3°C (9±5.5 °F) 150°C (300°F)
Download PDF /cat1.html" class="access-link"> Access full catalogue