Bulb and capillary thermostat, printed knob adjustment
Electrical connection
Internal junction block
Set point adjustment
Printed knob
Sensing element
Bulb and capillary
Action
Control
Contact Rating 230V
SPDT 15A
T° range min and max limits
-35 to +320°C
Types
Important Note: These thermostats are considered to be material by the standards of equipment for
potentially explosive atmospheres. They are intended to monitor or control the temperatures in hazardous
areas. Thermostat, housing and terminal block are indivisible. In gas explosive atmospheres, they can be used
in zones 1 or 2 in the presence of gas, smoke and fog, class IIC, surface temperature T6, and ambient
temperature on the enclosure from -50 to +60°C or from -50 to +70°C
In dust explosive atmospheres, they can
be used in zones 21 and 22
These thermostats have explosion-proof microswitch type II2Gb, Ex dIIC according to IEC/EN 60079-1, embedded
in an increased safety aluminum enclosure according to IEC/EN 60079-7.
Ex identification :
Gas explosive atmospheres:
II 2G Ex d e IIC T6
Dust explosive atmospheres:
Ex 2D Ex tb IIIC T85°C Db
Approvals: These products are ATEX and IECEx certified
Atex: pending; IECEx: pending
Housing: aluminum, 140 x 110 x 90mm (Dimensions without cable gland), with
epoxy painting, RAL7032 (thickness less than 0.2mm)
Temperature sensing element: oil filled bulb and capillary, liquid expansion principle. The
capillary is protected by a flexible corrugated stainless steel tube.
Electrical connection: On built-in junction block, 4mm², screw terminals. 7 terminals for
neutral, ground and line, including jumpers between input and output for neutral and ground. Large space
provided for connection.
A built in junction block, type Push-In® is available on request.
Cable glands: two M25 metal cable glands can be used for cable from 9 to 13mm or 13 to 16mm.
There is a cable locking saddle inside the enclosure, at each cable gland input.
Other cable glands for round cable, flat cable or independent conductors are available on request
Ground terminals: Two M4 grounding terminals with saddle are located on the outside of
enclosure. 2 grounding terminals are located on the junction block.
Adjustment: With knob printed in °C (°F on request). Adjustment is possible only after
removing the cover, and when the electrical supply is powered off.
Mounting: Wall mounting, by 2 holes dia. 6.5 mm in diagonal of a 95mm x 95mm square. 4 tabs
elevate the housing of 3mm to limit the thermal contact with the wall.
The housing rear face further
includes four M4 threaded holes 36.5 x75mm distance for mounting metal brackets and feet providing offset wall
mounting, pole or pipes
mounting (see the accessories in the last part of this catalog)
Contacts: SPDT (snap action contact)
Electrical rating: Suitable for power control, remote control of relay coils or PLCs
circuits, and direct power switching.
These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in
time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is
less than 100mA, or the switched power less than 800mW. Contact us for those applications that require
gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
Mechanical life: > 500.000 cycles
Voltage | Max rating (A) | Switch Electrical life (cycles) |
400VAC (KA type only) | 10 | 500000 |
250VAC | 15 | 500000 |
125VAC | 15 | 500000 |
0-15VDC | 15 | 500000 |
15-30VDC | 2 | 500000 |
References with standard differential | References with reduced differential | Temperature range (°C) | Capillary length (C, mm) | Bulb diameter (D, mm) | Bulb length (L, mm) | KA, standard differential*(°C) | KB, reduced differential*(°C) | Max temperature on bulb (°C) |
Y95KAA-2502522VK | Y95KBA-2502522VK | -25+25** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 50 |
Y95KAA-1001522VK | Y95KBA-1001522VK | -10+15** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 50 |
Y95KAA00005020VK | Y95KBA00005020VK | 0-50** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 60 |
Y95KAA00007052VK | Y95KBA00007052VK | 0-70 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA00007012VK | Y95KBA00007012VK | 0-70 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA02009050VK | Y95KBA02009050VK | 20-90 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA02009010VK | Y95KBA02009010VK | 20-90 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA01015050VK | Y95KBA01015050VK | 10-150 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA01015010VK | Y95KBA01015010VK | 10-150 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA08020001VK | Y95KBA08020001VK | 80-200 | 1500 | 4 | 100 | 10+/-4 | 6+/-4 | 320 |
Y95KAA05030001VK | Y95KBA05030001VK | 50-300 | 1500 | 4 | 100 | 10+/-4 | 6+/-4 | 320 |
*Reduced differential types are not suitable for 400VAC applications.
**The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it
is important to protect
the bulb and /or the capillary against the risk of freezing if a temperature
below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C. For these types, maximum
ambient temperature acceptable on enclosure : 60°C.
See to the last section of this catalogue for existing accessories
Bulb and capillary thermostat, printed knob adjustment
Electrical connection
Internal junction block
Set point adjustment
Screw driver
Sensing element
Bulb and capillary
Action
Control
Contact Rating 230V
SPDT 15A
T° range min and max limits
-35 to +320°C
Types
Important Note: These thermostats are considered to be material by the standards of equipment for
potentially explosive atmospheres. They are intended to monitor or control the temperatures in hazardous
areas. Thermostat, housing and terminal block are indivisible.
In gas explosive atmospheres, they can be used in zones 1 or 2 in the presence of gas, smoke and fog, class
IIC, surface temperature T6, and ambient temperature on the enclosure from -50 to +60°C, or from -50 to
+70°C
In dust explosive atmospheres, they can be used in zones 21 and 22
These thermostats have explosion-proof microswitch type II2Gb, Ex dIIC according to IEC/EN 60079-1, embedded
in an increased safety aluminum enclosure according to
IEC/EN 60079-7.
Ex identification :
Gas explosive atmospheres:
II 2G Ex d e IIC T6
Dust explosive atmospheres:
Ex 2D Ex tb IIIC T85°C Db
Approvals: These products are ATEX and IECEx certified
Atex: pending; IECEx: pending
Housing: aluminum, 140 x 110 x 90mm (Dimensions without cable gland), with epoxy painting, RAL7032 (thickness
less than 0.2mm)
Temperature sensing element: oil filled bulb and capillary, liquid expansion principle. The
capillary is protected by a flexible corrugated stainless steel tube.
Electrical connection: On built-in junction block, 4mm², screw terminals. 7 terminals for
neutral, ground and line, including jumpers between input and output for neutral and ground. Large space
provided for connection.
A built in junction block, type Push-In® is available on request.
Cable glands: two M25 metal cable glands can be used for cable from 9 to 13mm or 13 to 16mm.
There is a cable locking saddle inside the enclosure, at each cable gland input.
Other cable glands for round cable, flat cable or independent conductors are available on request
Ground terminals: Two M4 grounding terminals with saddle are located on the outside of
enclosure. 2 grounding terminals are located on the junction block.
Adjustment: By screw driver, with dial printed in °C (°F on request). Adjustment is possible
only after removing the cover, and when the electrical supply is powered off.
Mounting: Wall mounting, by 2 holes dia. 6.5 mm in diagonal of a 95mm x 95mm square. 4 tabs
elevate the housing of 3mm to limit the thermal contact with the wall.
The housing rear face further includes four M4 threaded holes 36.5 x75mm distance for mounting metal brackets
and feet providing offset wall mounting, pole or pipes mounting (see the accessories in the last part of this
catalog)
Contacts: SPDT (snap action contact)
Electrical rating: Suitable for power control, remote control of relay coils or PLCs
circuits, and direct power switching.
These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in
time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is
less than 100mA, or the switched power less than 800mW. Contact us for those applications that require
gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
Mechanical life: > 500.000 cycles
Voltage | Max rating (A) | Switch Electrical life (cycles) |
400VAC (KA type only) | 10 | 500000 |
250VAC | 15 | 500000 |
125VAC | 15 | 500000 |
0-15VDC | 15 | 500000 |
15-30VDC | 2 | 500000 |
References with standard differential | References with reduced differential | Temperature range (°C) | Capillary length (C, mm) | Bulb diameter (D, mm) | Bulb length (L, mm) | KA, standard differential*(°C) | KB, reduced differential*(°C) | Max temperature on bulb (°C) |
Y95KAA-2502522VK | Y95KBA-2502522VK | -25+25** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 50 |
Y95KAA-1001522VK | Y95KBA-1001522VK | -10+15** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 50 |
Y95KAA00005020VK | Y95KBA00005020VK | 0-50** | 1500 | 6.4 | 152 | 3+/-2 | 2+/-1 | 60 |
Y95KAA00007052VK | Y95KBA00007052VK | 0-70 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA00007012VK | Y95KBA00007012VK | 0-70 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA02009050VK | Y95KBA02009050VK | 20-90 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA02009010VK | Y95KBA02009010VK | 20-90 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA01015050VK | Y95KBA01015050VK | 10-150 | 1500 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA01015010VK | Y95KBA01015010VK | 10-150 | 3000 | 4.8 | 120 | 5+/-3 | 3+/-2 | 160 |
Y95KAA08020001VK | Y95KBA08020001VK | 80-200 | 1500 | 4 | 100 | 10+/-4 | 6+/-4 | 320 |
Y95KAA05030001VK | Y95KBA05030001VK | 50-300 | 1500 | 4 | 100 | 10+/-4 | 6+/-4 | 320 |
*Reduced differential types are not suitable for 400VAC applications.
**The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it
is important to protect
the bulb and /or the capillary against the risk of freezing if a temperature
below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C. For these types, maximum
ambient temperature acceptable on enclosure : 60°C.
See to the last section of this catalogue for existing accessories