DIMENSIONS
MAIN FEATURES
Use: low voltage circuits
Main applications: steam generators, coffee machines, vending machines, air conditioning
pumps, dehumidifiers, tanks. The side mounting allows to adjust the level on big size tanks.
Stem material: PBT
Float material: hollow PBT
Mounting: horizontal on ½”NPT female fitting
Contact configuration: It opens when the float touch the stem. Two positions are
possible:
-The float is on the top of the stem: contact is normally open (the float touch the stem when there
is no liquid), and will close when the level rises and the float goes up
-The float is pending downside under the stem: contact is normally closed (the float does not touch
the stem) and will open when the level rises and the float goes up and touch the stem.
Electrical rating:
Low voltage type: maximum power 10 W (VA), max 0.5Amp, max voltage 110VAC.
230VAC type: max power 40 W (VA), max 1Amp. Values for resistive circuit. For inductive or
capacitive loads, a contact protection circuit must be used.
Contact resistance: 150mOhms maxi (wires not included)
Wires: AWG24 cable, UL style 2464, PVC insulated, length 100, 500, 1000 or 2000 mm
Liquid limits: to be used with liquids chemically compatible with PBT, specific gravity
higher than 0.9, dynamic viscosity higher than 0.5x10-4 Pa.s and lower than 10-2 Pa.s, without
magnetic particles.
Ambient temperature: -20+80°C
Maximum pressure: 1 bar (15 PSI)
Options: other cable length, electrical rating 70W, 1A, 250VAC