  • ULTIMHEAT : Explosion proof thermostats and limiters, connection inside EX « e » aluminum housing with built-in connection block. Bulb and capillary thermostat. Type Y94

    Thermostats and limiters, connection inside EX « e » aluminum housing with built-in connection block
    Bulb and capillary thermostat, printed knob adjustment
    Electrical connection Set point adjustment Mounting Action Contact Rating 230V T° range min and max limits Types
    Internal junction block Printed knob Bulb and capillary Control SPDT 15A -35 to +320°C Y94KAA
    Y94KBA
    General rules for installation:
    Important Note: These thermostats are considered to be material by the standards of equipment for potentially explosive atmospheres. They are intended to monitor or control the temperatures in hazardous areas. Thermostat, housing and terminal block are indivisible. In gas explosive atmospheres, they can be used in zones 1 or 2 in the presence of gas, smoke and fog, class IIC, surface temperature T6, and ambient temperature on the enclosure from -50 to +60°C or from -50 to +70°C
    In dust explosive atmospheres, they can be used in zones 21 and 22
    These thermostats have explosion-proof microswitch type II2Gb, Ex dIIC according to IEC/EN 60079-1, embedded in an increased safety aluminum enclosure according to IEC/EN 60079-7.
    Ex identification :
    Gas explosive atmospheres:
    II 2G Ex d e IIC T6
    Dust explosive atmospheres:
    Ex 2D Ex tb IIIC T85°C Db
    Approvals: These products are ATEX and IECEx certified
    Atex: pending; IECEx: pending
    Housing: aluminum, 140 x 110 x 90mm (Dimensions without cable gland), with epoxy painting, RAL7032 (thickness less than 0.2mm)
    Temperature sensing element: oil filled bulb and capillary, liquid expansion principle. The capillary is protected by a flexible corrugated stainless steel tube.
    Electrical connection: On built-in junction block, 4mm², screw terminals. 7 terminals for neutral, ground and line, including jumpers between input and output for neutral and ground. Large space provided for connection.
    A built in junction block, type Push-In® is available on request.
    Cable glands: two M25 metal cable glands can be used for cable from 9 to 13mm or 13 to 16mm. There is a cable locking saddle inside the enclosure, at each cable gland input.
    Other cable glands for round cable, flat cable or independent conductors are available on request
    Ground terminals: Two M4 grounding terminals with saddle are located on the outside of enclosure. 2 grounding terminals are located on the junction block.
    Adjustment: With knob printed in °C (°F on request). Adjustment is possible only after removing the cover, and when the electrical supply is powered off.
    Mounting: Wall mounting, by 2 holes dia. 6.5 mm in diagonal of a 95mm x 95mm square. 4 tabs elevate the housing of 3mm to limit the thermal contact with the wall.
    The housing rear face further includes four M4 threaded holes 36.5 x75mm distance for mounting metal brackets and feet providing offset wall mounting, pole or pipes
    mounting (see the accessories in the last part of this catalog)
    Contacts: SPDT (snap action contact)
    Electrical rating: Suitable for power control, remote control of relay coils or PLCs circuits, and direct power switching.
    These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is less than 100mA, or the switched power less than 800mW. Contact us for those applications that require gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
    Mechanical life: > 500.000 cycles
    Voltage Max rating (A) Switch Electrical life (cycles)
    400VAC (KA type only) 10 500000
    250VAC 15 500000
    125VAC 15 500000
    0-15VDC 15 500000
    15-30VDC 2 500000

    References with standard differential References with reduced differential Temperature range (°C) Capillary length (C, mm) Bulb diameter (D, mm) Bulb length (L, mm) KA, standard differential*(°C) KB, reduced differential*(°C) Max temperature on bulb (°C)
    Y95KAA-2502522VK Y95KBA-2502522VK -25+25** 1500 6.4 152 3+/-2 2+/-1 50
    Y95KAA-1001522VK Y95KBA-1001522VK -10+15** 1500 6.4 152 3+/-2 2+/-1 50
    Y95KAA00005020VK Y95KBA00005020VK 0-50** 1500 6.4 152 3+/-2 2+/-1 60
    Y95KAA00007052VK Y95KBA00007052VK 0-70 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA00007012VK Y95KBA00007012VK 0-70 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA02009050VK Y95KBA02009050VK 20-90 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA02009010VK Y95KBA02009010VK 20-90 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA01015050VK Y95KBA01015050VK 10-150 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA01015010VK Y95KBA01015010VK 10-150 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA08020001VK Y95KBA08020001VK 80-200 1500 4 100 10+/-4 6+/-4 320
    Y95KAA05030001VK Y95KBA05030001VK 50-300 1500 4 100 10+/-4 6+/-4 320
    *Reduced differential types are not suitable for 400VAC applications.
    **The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it is important to protect the bulb and /or the capillary against the risk of freezing if a temperature below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C. For these types, maximum ambient temperature acceptable on enclosure : 60°C.
    See to the last section of this catalogue for existing accessories

    Thermostats and limiters, connection inside EX « e » aluminum housing with built-in connection block
    Bulb and capillary thermostat, screw driver adjustment
    Electrical connection Set point adjustment Mounting Action Contact Rating 230V T° range min and max limits Types
    Internal junction block Screw driver Bulb and capillary Control SPDT 15A -35 to +320°C Y95KAC
    Y95KBC
    General rules for installation:
    Important Note: These thermostats are considered to be material by the standards of equipment for potentially explosive atmospheres. They are intended to monitor or control the temperatures in hazardous areas. Thermostat, housing and terminal block are indivisible.
    In gas explosive atmospheres, they can be used in zones 1 or 2 in the presence of gas, smoke and fog, class IIC, surface temperature T6, and ambient temperature on the enclosure from -50 to +60°C, or from -50 to +70°C
    In dust explosive atmospheres, they can be used in zones 21 and 22
    These thermostats have explosion-proof microswitch type II2Gb, Ex dIIC according to IEC/EN 60079-1, embedded in an increased safety aluminum enclosure according to
    IEC/EN 60079-7.
    Ex identification :
    Gas explosive atmospheres:
    II 2G Ex d e IIC T6
    Dust explosive atmospheres:
    Ex 2D Ex tb IIIC T85°C Db
    Approvals: These products are ATEX and IECEx certified
    Atex: pending; IECEx: pending
    Housing: aluminum, 140 x 110 x 90mm (Dimensions without cable gland), with epoxy painting, RAL7032 (thickness less than 0.2mm)
    Temperature sensing element: oil filled bulb and capillary, liquid expansion principle. The capillary is protected by a flexible corrugated stainless steel tube.
    Electrical connection: On built-in junction block, 4mm², screw terminals. 7 terminals for neutral, ground and line, including jumpers between input and output for neutral and ground. Large space provided for connection.
    A built in junction block, type Push-In® is available on request.
    Cable glands: two M25 metal cable glands can be used for cable from 9 to 13mm or 13 to 16mm. There is a cable locking saddle inside the enclosure, at each cable gland input.
    Other cable glands for round cable, flat cable or independent conductors are available on request
    Ground terminals: Two M4 grounding terminals with saddle are located on the outside of enclosure. 2 grounding terminals are located on the junction block.
    Adjustment: By screw driver, with dial printed in °C (°F on request). Adjustment is possible only after removing the cover, and when the electrical supply is powered off.
    Mounting: Wall mounting, by 2 holes dia. 6.5 mm in diagonal of a 95mm x 95mm square. 4 tabs elevate the housing of 3mm to limit the thermal contact with the wall.
    The housing rear face further includes four M4 threaded holes 36.5 x75mm distance for mounting metal brackets and feet providing offset wall mounting, pole or pipes mounting (see the accessories in the last part of this catalog)
    Contacts: SPDT (snap action contact)
    Electrical rating: Suitable for power control, remote control of relay coils or PLCs circuits, and direct power switching.
    These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is less than 100mA, or the switched power less than 800mW. Contact us for those applications that require gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
    Mechanical life: > 500.000 cycles
    Voltage Max rating (A) Switch Electrical life (cycles)
    400VAC (KA type only) 10 500000
    250VAC 15 500000
    125VAC 15 500000
    0-15VDC 15 500000
    15-30VDC 2 500000

    References with standard differential References with reduced differential Temperature range (°C) Capillary length (C, mm) Bulb diameter (D, mm) Bulb length (L, mm) KA, standard differential*(°C) KB, reduced differential*(°C) Max temperature on bulb (°C)
    Y95KAA-2502522VK Y95KBA-2502522VK -25+25** 1500 6.4 152 3+/-2 2+/-1 50
    Y95KAA-1001522VK Y95KBA-1001522VK -10+15** 1500 6.4 152 3+/-2 2+/-1 50
    Y95KAA00005020VK Y95KBA00005020VK 0-50** 1500 6.4 152 3+/-2 2+/-1 60
    Y95KAA00007052VK Y95KBA00007052VK 0-70 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA00007012VK Y95KBA00007012VK 0-70 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA02009050VK Y95KBA02009050VK 20-90 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA02009010VK Y95KBA02009010VK 20-90 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA01015050VK Y95KBA01015050VK 10-150 1500 4.8 120 5+/-3 3+/-2 160
    Y95KAA01015010VK Y95KBA01015010VK 10-150 3000 4.8 120 5+/-3 3+/-2 160
    Y95KAA08020001VK Y95KBA08020001VK 80-200 1500 4 100 10+/-4 6+/-4 320
    Y95KAA05030001VK Y95KBA05030001VK 50-300 1500 4 100 10+/-4 6+/-4 320
    *Reduced differential types are not suitable for 400VAC applications.
    **The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it is important to protect the bulb and /or the capillary against the risk of freezing if a temperature below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C. For these types, maximum ambient temperature acceptable on enclosure : 60°C.
    See to the last section of this catalogue for existing accessories

    Download PDF
    Access full catalogue



    *ULTIMHEAT ® is a registered trademark
    Various types of Heaters :Flexible Rectangular Silicone Heaters / Anti Freeze Band Heaters / Band Heaters / Silicone Band Drum Heaters / Flexible Jacket Heater / Accessories and Options
    Temperature Controls and Safety Devices: Creep action fixed setting strip thermostat / Snap action fixed setting strip thermostat / Snap action fixed setting disc thermostat / Thermal Fuses / Thermocouple / Resistance Temperature Devices (RTD) / Bulb and Capillary Control/ Bimetal surface control/ Remote bulb thermostat/ Remote electric temperature control