  • ULTIMHEAT : Explosion proof bulb and capillary thermostats for incorporation Temperature control, front mounting. Type KAA

    Explosion proof bulb and capillary thermostats for incorporation
    Cable electrical connection (product approval)
    Temperature control, front mounting
    Electrical connection Set point adjustment Mounting Action Contact Rating 230V T° range min and max limits Types
    Cable 10mm shaft Front, 2 M4 screws Control SPDT 15A -35 to +320°C KAA-3
    KBA-3
    General rules for installation:
    Important note: This thermostat is considered as a product by the standards of equipment for potentially explosive atmospheres.
    Its incorporation into equipment or inside an enclosure does not request the approval of the entire device by a professional competent certified body.
    These models with knob adjustment and front mounting allow incorporation inside most existing “Ex e” junction boxes in aluminum or polyester and inside a fitting height of 71 mm.
    These thermostats are intended to monitor or control temperatures in hazardous areas.
    They can be used in zones 1 or 2 with gas, smoke and fog, class IIC, surface temperatureT5 or T6, and for ambient temperature on housing of -50 to +80°C(T5) , or -50 to +70°C (T6).
    This thermostat uses a flameproof micro-switch type II2Gb, Ex dIIC T5/T6.
    Electrical connections at end of the cable must be made inside increased safety «EX-e» enclosure, or explosion proof enclosure «Ex-d» or outside hazardous area
    The thermostat capillary exit must be performed by a cable gland with gasket adapted to the diameter of the capillary and providing the level of protection required by the standard. Outside housings, electrical cable and thermostat capillary must be mechanically protected.
    Approvals: These thermostats are ATEX and IECEx certified.
    Atex: INERIS13ATEX0066-X ; IECEx: INE13.0099-X
    Housing: aluminum, 82,2 x 37 x 56,5mm (Dimensions without shaft and knob)
    Bulb and capillary: Copper for temperature ranges up to 50°C, stainless steel over 50°C. Capillary length 1500 mm or 3000 mm. Capillary minimum bending radius 5mm.
    Temperature sensing element: oil filled bulb and capillary.
    Electrical connection: H05SS-F silicone insulated cable, 3 x 1.5 mm², standard length 3m. Wire ends with crimped terminals. Other lengths on request.
    Ground terminals: Two M4 grounding terminals with saddle are located on the side.
    Adjustment: Dia. 6 mm shaft with 4.6 mm flat, length 10 mm.
    Other shaft lengths available on request:
    -20 mm: the third character of the reference (A) becomes M;
    -30 mm: the third character of the reference (A) becomes J.
    Mounting: Front bracket with 2 x M4 threads, 28 mm distance
    Contacts: SPDT (snap action contact)
    Electrical rating: Suitable for power control, remote control of relay coils or PLCs circuits.
    These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is less than 100mA, or the switched power less than 800mW. Contact us for those applications that require gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
    Mechanical life: > 500.000 cycles
    Voltage Max rating (A) Switch Electrical life (cycles)
    400VAC (KA type only) 10 500000
    250VAC 15 500000
    125VAC 15 500000
    0-15VDC 15 500000
    15-30VDC 2 500000

    Main references with 3m cable length (L1)
    References with standard differential References with reduced differential Temperature range (°C) Capillary length (C, mm) Bulb diameter (D2, mm) Bulb length (L2, mm) KA, standard differential*(°C) KB, reduced differential*(°C) Max temperature on bulb (°C)
    KAA-2502522C3 KBA-2502522C3 -25+25** 1500 6.4 152 3+/-2 2+/-1 50
    KAA-1001522C3 KBA-1001522C3 -10+15** 1500 6.4 152 3+/-2 2+/-1 50
    KAA00005020C3 KBA00005020C3 0-50** 1500 6.4 152 3+/-2 2+/-1 60
    KAA00007052C3 KBA00007052C3 0-70 1500 4.8 120 5+/-3 3+/-2 160
    KAA00007012C3 KBA00007012C3 0-70 3000 4.8 120 5+/-3 3+/-2 160
    KAA02009050C3 KBA02009050C3 20-90 1500 4.8 120 5+/-3 3+/-2 160
    KAA02009010C3 KBA02009010C3 20-90 3000 4.8 120 5+/-3 3+/-2 160
    KAA01015050C3 KBA01015050C3 10-150 1500 4.8 120 5+/-3 3+/-2 160
    KAA01015010C3 KBA01015010C3 10-150 3000 4.8 120 5+/-3 3+/-2 160
    KAA08020001C3 KBA08020001C3 80-200 1500 4 100 10+/-4 6+/-4 320
    KAA05030001C3 KBA05030001C3 50-300 1500 4 100 10+/-4 6+/-4 320
    *Reduced differential types are not suitable for 400VAC applications.
    **The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it is important to protect the bulb and /or the capillary against the risk of freezing if a temperature below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C.
    Go to the last section of this catalogue for knobs, dials, bezels and other accessories
    Explosion proof bulb and capillary thermostats for incorporation
    Cable electrical connection (product approval)
    Temperature control or high limit, front mounting
    Electrical connection Set point adjustment Mounting Action Contact Rating 230V T° range min and max limits Types
    Cable Screwdriver Front, 2 M4 screws Control SPDT 15A -35 to +320°C KAC-3
    KBC-3
    General rules for installation:
    Important note: This thermostat is considered as a product by the standards of equipment for potentially explosive atmospheres.
    Its incorporation into equipment or inside an enclosure does not request the approval of the entire device by a professional competent certified body.
    These models with front mounting allow incorporation inside most existing “Ex e” junction boxes in aluminum or polyester and inside a fitting height of 60 mm.
    These thermostats are intended to monitor or control temperatures in hazardous areas.
    They can be used in zones 1 or 2 with gas, smoke and fog, class IIC, surface temperatureT5 or T6, and for ambient temperature on housing of -50 to +80°C(T5) , or -50 to +70°C (T6).
    This thermostat uses a flameproof micro-switch type II2Gb, Ex dIIC T5/T6.
    Electrical connections at end of the cable must be made inside increased safety «EX-e» enclosure, or explosion proof enclosure «Ex-d» or outside hazardous area
    The thermostat capillary exit must be performed by a cable gland with gasket adapted to the diameter of the capillary and providing the level of protection required by the standard. Outside housings, electrical cable and thermostat capillary must be mechanically protected.
    Approvals: These thermostats are ATEX and IECEx certified.
    Atex: INERIS13ATEX0066-X ; IECEx: INE13.0099-X
    Housing: aluminum, 82,2 x 37 x 57,5mm (Dimensions without printed dial)
    Bulb and capillary: Copper for temperature ranges up to 50°C, stainless steel over 50°C. Capillary length 1500 mm or 3000 mm. Capillary minimum bending radius 5mm.
    Temperature sensing element: oil filled bulb and capillary.
    Electrical connection: H05SS-F silicone insulated cable, 3 x 1.5 mm², standard length 3m. Wire ends with crimped terminals. Other lengths on request.
    Ground terminals: Two M4 grounding terminals with saddle are located on the side.
    Adjustment: with screw driver slot. When used as a temperature limiter, this adjustment screw can be sealed with varnish or epoxy resin. For adjustable temperature set point applications, printed dials are available and must be ordered separately.
    Mounting: Front bracket with 2 x M4 threads, 28 mm distance
    Contacts: SPDT (snap action contact)
    Electrical rating: Suitable for power control, remote control of relay coils or PLCs circuits.
    These devices use silver contacts or silver alloy contacts. Due to the possible oxidation of the contacts in time, we do not recommend the use of AC or DC low-voltage circuits (24V or less) if the switched intensity is less than 100mA, or the switched power less than 800mW. Contact us for those applications that require gold-plated contacts. The electrical ratings given are normalized resistive circuit values.
    Mechanical life: > 500.000 cycles
    Voltage Max rating (A) Switch Electrical life (cycles)
    400VAC (KA type only) 10 500000
    250VAC 15 500000
    125VAC 15 500000
    0-15VDC 15 500000
    15-30VDC 2 500000

    Main references with 3m cable length (L1)
    References with standard differential References with reduced differential Temperature range (°C) Capillary length (C, mm) Bulb diameter (D2, mm) Bulb length (L2, mm) KA, standard differential*(°C) KB, reduced differential*(°C) Max temperature on bulb (°C)
    KAC-2502522C3 KBC-2502522C3 -25+25** 1500 6.4 152 3+/-2 2+/-1 50
    KAC-1001522C3 KBC-1001522C3 -10+15** 1500 6.4 152 3+/-2 2+/-1 50
    KAC00005020C3 KBC00005020C3 0-50** 1500 6.4 152 3+/-2 2+/-1 60
    KAC00007052C3 KBC00007052C3 0-70 1500 4.8 120 5+/-3 3+/-2 160
    KAC00007012C3 KBC00007012C3 0-70 3000 4.8 120 5+/-3 3+/-2 160
    KAC02009050C3 KBC02009050C3 20-90 1500 4.8 120 5+/-3 3+/-2 160
    KAC02009010C3 KBC02009010C3 20-90 3000 4.8 120 5+/-3 3+/-2 160
    KAC01015050C3 KBC01015050C3 10-150 1500 4.8 120 5+/-3 3+/-2 160
    KAC01015010C3 KBC01015010C3 10-150 3000 4.8 120 5+/-3 3+/-2 160
    KAC08020001C3 KBC08020001C3 80-200 1500 4 100 10+/-4 6+/-4 320
    KAC05030001C3 KBC05030001C3 50-300 1500 4 100 10+/-4 6+/-4 320
    *Reduced differential types are not suitable for 400VAC applications.
    **The filling liquid of these thermostatic assemblies has a freezing temperature below -40 ° C. However it is important to protect the bulb and /or the capillary against the risk of freezing if a temperature below -35 ° C can be reached in operation. Acceptable storage temperature: -50 ° C.
    Go to the last section of this catalogue for knobs, dials, bezels and other accessories

    Download PDF
    Access full catalogue



    *ULTIMHEAT ® is a registered trademark
    Various types of Heaters :Flexible Rectangular Silicone Heaters / Anti Freeze Band Heaters / Band Heaters / Silicone Band Drum Heaters / Flexible Jacket Heater / Accessories and Options
    Temperature Controls and Safety Devices: Creep action fixed setting strip thermostat / Snap action fixed setting strip thermostat / Snap action fixed setting disc thermostat / Thermal Fuses / Thermocouple / Resistance Temperature Devices (RTD) / Bulb and Capillary Control/ Bimetal surface control/ Remote bulb thermostat/ Remote electric temperature control

    Blue Ink Company Limited
    Silicone Flexible Heating Surface Heater Manufacturer and ULTIMHEAT Product Distributor in Thailand and ASEAN
    Morning Dew Building, 41/3 – 41/4 Soi Sukhumvit46 Sukhumvit Rd. Phrakanong Klongtoey Bangkok 10110 Thailand
    Tel. +66(0)27135196 / Fax. +66(0)27135197
    E-mail: infoblueink@ultimheat.com / Website: www.ultimheat.co.th